Umiat Corridor Project
Itkillik River Station (DUS1)

Station Information

Site Description

Station Name: Itkilik River Station
Location: Itkilik River
Coordinates: N68 52 00.80497, W150 02 20.737 (WGS 84)
Elevation: 429.2 m

Notes: Elevation reference: Geoid model

Station History

  • Site Commissioned: 05/17/2009

Sensor Details:

  • Images: CC640 Digital Camera (2)
    • Image Trigger Interval : 30-minutes
    • Image Retrieval Interval : One every hour
  • Air Temperature: HMP45C Vaisala AT/RH sensor
    • RH Accuracy @20°C: 62% RH ( 0-90%), 63% RH (90-100%)
    • Temperature Accuracy: 60.2°C at 20°C; 60.4°C at -40°C
    • Operating Range: -40°C to +60°C
    • RH Range: 0 to 100%
    • Installation: In 12-gill radiation shield, non-aspirated
    • Height: 2 meters (6.6 feet)
    • Output Units: °C
    • Scan Interval: 60 seconds
  • Barometric Pressure : CSI Model CS106 Vaisala PTB110 Barometer
    • Installation: inside the datalogger enclosure
    • Height: about 1.5 m
    • Output Units: hPa (mb)
    • Scan Interval: Hourly
  • Water Level : Aquistar SDI12 Water Level Sensor (pressure + temperature)
    • Resolution: 16 bit
    • Accuracy: ± 0.06% FSO (typical)
    • Operating Range: -5° C to 70° C
    • Installation: ?
  • Datalogger: Campbell Scientific CR1000
    • Operating Temperature Range: -55°C to +85°C
  • Radio: Freewave FGR-115RC
    • Frequency: 900 MHz Spread Spectrum
Copyright © 2006 Water and Environmental Research Center