Umiat Corridor Project |
Hatbox Mesa Met Station
(DUM7) |
|
|
|
Photo
Gallery |
|
Station Information
|
Site Description
Station Name: Hatbox Mesa Met Station
Location: West Chandler mid-Basin
Coordinates: 68.7543
, -152.5730
(WGS 84)
Elevation: NGVD 1929: 624 m
Notes:
- Elevation from hand-held GPS
|
Station History
- Site Commissioned: 09/01/2010
|
Sensor Details:
- Images: CC640
Digital Camera
- Image Trigger Interval : 30-minutes
- Image Retrieval Interval : One every hour
- Wind Speed: RM
Young 05103-L Wind Monitor
- Accuracy: +/- 0.3 m/s (+/- 0.6 mph)
- Operating Range: 0 to 60 m/s (0 to 134 mph)
- Starting Threshold: 1 m/s (2.2 mph).
- Height: 3 m
- Output Units: meters per second
- Scan Interval: 5 seconds
- Wind Direction: RM
Young 05103-L Wind Monitor
- Operating Range: 0 to 360 deg (mechanical) true north (0 to 355 electrical, 5 deg open)
- Starting Threshold: 1.1 m/s (2.2 mph) 10 deg displacement
- Installation: Align true north
- Height: 3 meters
- Output Units: degrees true north
- Scan Interval: 5 seconds
- Air Temperature: HMP45C Vaisala AT/RH sensor
- RH Accuracy @20°C: 62% RH ( 0-90%),
63% RH (90-100%)
- Temperature Accuracy: 60.2°C at 20°C;
60.4°C at -40°C
- Operating Range: -40°C to +60°C
- RH Range: 0 to 100%
- Installation: In 12-gill radiation shield, non-aspirated
- Height: 2 meters (6.6 feet)
- Output Units: °C
- Scan Interval: 60 seconds
- Air Temperature - Cold Range: Triplicate YSI Series 44033 thermistors
- Operating Range: -80°C to +75°C
- Installation: In 6 plate Gill Radiation Shield, non-aspirated
- Height: 2 meters (6.6 feet)
- Output Units: kW, °C.
- Scan Interval: 60 seconds
- Barometric Pressure : CSI Model CS106 Vaisala PTB110 Barometer
- Installation: inside the datalogger enclosure
- Height: about 1.5 m
- Output Units: hPa (mb)
- Scan Interval: Hourly
- Summer Precipitation: Texas
Electronics TE525MM (Tipping Bucket Gauge)
- Resolution (1 Tip) : 0.004 in (0.1 mm)
- Accuracy: ±1% at rates up to 1"/hr
- Installation: wind shield
- Height: 1 m
- Snow Depth: Campbell
Scientific SR50 (sonic ranging sensor)
- Operating Range: 0.5 to 10 meters
- Resolution: 0.1 mm
- Accuracy: to 1 cm or 0.4 percent of distance to target
- Installation: Point straight down on a flat surface
- Height: ~1.5 m
- Net Radiation: Kipp
and Zonen NR-Lite
- Installation: Orient to south to minimize shadow effect
from pole.
- Accuracy: Varies with temperature, wind speed and sensor
symmetry
- Height: ~1 m
- Soil Temperature (ST1,ST2,ST3) GWS YSI Series 44033 (Thermistors)
- Depths: <1cm (surface), at top of soil interface, 3 thermistors
- Soil Temperature Profile (STP1,STPn,..,STP12) GWS YSI
Series 44033 (Thermistors)
- Installation: In back-filled bored hole
- Depths: 0-150 cm; 1-12 thermistors (based on actual depth
of bored drill hole)
- Soil Moisture Profile (SM1,SM2,SM3,SM4) Campbell
Scientific CS616 Soil-Moisture Probe
- Installation: horizontal orientation in back-filled hole
- Depths: 10cm, 20cm, 30cm, 40cm
- Datalogger: Campbell
Scientific CR1000
- Operating Temperature Range: -55°C to +85°C
- Radio: Freewave
FGR-115RC
- Frequency: 900 MHz Spread Spectrum
|
|