site = nslope/sagwon_hill # reverse-annotated 22nov04 ki -- needs to be checked # field rewiring and asbuilt, 2july2005 ki # single-ended input channels SE1 WD-10m SE2 MUX2-H1 SE3 MUX1-H1 SE4 MUX1-L1 SE5 RadioBatt_vdiv SE6 -- SE7 AT-1m SE8 AT-3m SE9 AT-10m SE10 RH-1m SE11 RH-3m SE12 RH-10m # differential input channels DIFF1 -- DIFF2 MUX1-D1 DIFF3 -- DIFF4 -- DIFF5 -- DIFF6 -- # excitation channels E1 MUX1-L2,MUX2-L1 E2 WD-10m, RH-10m E3 AT-10m, WD-3m # pulse-count inputs P1 WS-1m P2 WS-10m # control ports, input or output C1 MUX2-RES C2 MUX1-RES C3 MUX1-CLK,MUX1-CLK C4 ATRH-1m-3m-relay C5 SnowDepth-SDI12 C6 RADIO-EN C7 -- C8 RAIN-SW # first multiplexer inputs MUX1-1-H1 TLW+ MUX1-1-L1 TLW- MUX1-1-H2 -- MUX1-1-L2 -- MUX1-2-H1 ALW+ MUX1-2-L1 ALW- MUX1-2-H2 -- MUX1-2-L2 -- MUX1-3-H1 ISW+ MUX1-3-L1 ISW- MUX1-3-H2 -- MUX1-3-L2 -- MUX1-4-H1 RSW+ MUX1-4-L1 RSW- MUX1-4-H2 -- MUX1-4-L2 -- MUX1-5-H1 Net+ MUX1-5-L1 Net- MUX1-5-H2 -- MUX1-5-L2 -- MUX1-6-H1 lycor-bad+ MUX1-6-L1 lycor-bad- MUX1-6-H2 -- MUX1-6-L2 -- MUX1-7-H1 -- MUX1-7-L1 -- MUX1-7-H2 -- MUX1-7-L2 WD-3m MUX1-8-H1 -- MUX1-8-L1 -- MUX1-8-H2 -- MUX1-8-L2 -- MUX1-9-H1 -- MUX1-9-L1 -- MUX1-9-H2 -- MUX1-9-L2 -- MUX1-10-H1 -- MUX1-10-L1 -- MUX1-10-H2 -- MUX1-10-L2 -- MUX1-11-H1 -- MUX1-11-L1 -- MUX1-11-H2 -- MUX1-11-L2 -- MUX1-12-H1 -- MUX1-12-L1 -- MUX1-12-H2 -- MUX1-12-L2 -- MUX1-13-H1 -- MUX1-13-L1 -- MUX1-13-H2 -- MUX1-13-L2 -- MUX1-14-H1 -- MUX1-14-L1 -- MUX1-14-H2 -- MUX1-14-L2 -- MUX1-15-H1 -- MUX1-15-L1 -- MUX1-15-H2 -- MUX1-15-L2 -- MUX1-16-H1 -- MUX1-16-L1 -- MUX1-16-H2 -- MUX1-16-L2 -- # second multiplexer inputs MUX2-1-H1 therm-m0 MUX2-1-L1 -- MUX2-1-H2 therm-m15 MUX2-1-L2 -- MUX2-2-H1 therm-p20 MUX2-2-L1 -- MUX2-2-H2 therm-m5 MUX2-2-L2 -- MUX2-3-H1 therm-m30 MUX2-3-L1 -- MUX2-3-H2 therm-m20 MUX2-3-L2 -- MUX2-4-H1 therm-m10 MUX2-4-L1 -- MUX2-4-H2 therm-p10 MUX2-4-L2 -- MUX2-5-H1 therm-p30 MUX2-5-L1 -- MUX2-5-H2 therm-m40 MUX2-5-L2 -- MUX2-6-H1 therm-m55 MUX2-6-L1 -- MUX2-6-H2 therm-m70 MUX2-6-L2 -- MUX2-7-H1 TLW-dome-temp MUX2-7-L1 -- MUX2-7-H2 ALW-dome-temp MUX2-7-L2 -- MUX2-8-H1 therm2-m0 MUX2-8-L1 -- MUX2-8-H2 therm2-m5 MUX2-8-L2 -- MUX2-9-H1 therm2-m10 MUX2-9-L1 -- MUX2-9-H2 therm2-m20 MUX2-9-L2 -- MUX2-10-H1 therm2-m50 MUX2-10-L1 -- MUX2-10-H2 therm2-m90 MUX2-10-L2 -- MUX2-11-H1 therm2-m150 MUX2-11-L1 -- MUX2-11-H2 therm2-m250 MUX2-11-L2 -- MUX2-12-H1 therm2-m450 MUX2-12-L1 -- MUX2-12-H2 therm2-m650 MUX2-12-L2 -- MUX2-13-H1 therm2-m850 MUX2-13-L1 -- MUX2-13-H2 therm2-m1050 MUX2-13-L2 -- MUX2-14-H1 -- MUX2-14-L1 -- MUX2-14-H2 -- MUX2-14-L2 -- MUX2-15-H1 -- MUX2-15-L1 -- MUX2-15-H2 -- MUX2-15-L2 -- MUX2-16-H1 -- MUX2-16-L1 -- MUX2-16-H2 -- MUX2-16-L2 --